2AB22HM1F2E0 - Goulds Pumps Aqua Boost II Booster System

Click to Compare

  • Model:  2AB22HM1F2E0
  • Manufactured by:  Goulds
  • Product Availability: Obsolete
  • Goulds 2AB22HM1F2E0 Specifications: Goulds 2AB22HM1F2E0 Specifications
 
This model number is obsolete:
Contact us for replacement model


2AB22HM1F2E0

1.5 HP - 208/230 Volt - 30 GPM Max - Single Phase - Stainless Steel Pump

FEATURES

The AquaBoost II variable speed pump controller and complete booster package kits, provide an economical answer for municipal water district customers with low water pressure. Both domestic and light commercial applications can benefit. As water use increases, the AquaBoost II changes pump speed to maintain pressure. Large supply tanks are eliminated and less wear and tear on your pump and motor.

Think of it as Cruise Control for your pump! The AquaBoost II is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration and fire suppression systems. Light commercial applications up to 100 GPM at 45 PSI boost. The AquaBoost II is available as either a separate controller or as part of a complete pump package with everything you need to plumb it to a domestic water line.

Package Includes:
  • 2 HP controller
  • Wall mount kit
  • 208-230 V input
  • HMS stainless steel pump
  • Transducer
  • V6P (2 gallon) tank, pressure gauge and discharge pipe tee
  • Controller is pre-wired. Flows to 30 GPM.
AQUABOOST CONTROLLER FEATURES
  • Input Power* - 208-230V ±15%, single phase (controller only)
  • Output Power - Up to 230V three phase (based on input voltage). Motor rated for 208-230V, ±10%.
  • Maximum Output Current - 4.2 amps - 1AB2 (1 HP) - 6.9 amps - 2AB2 (2 HP)
  • Input Controls - Up and down buttons to set pressure.
  • Signal Lights - Power on, pump running, inverter stopped, pump stopped, standby, faults/errors.
  • Electrical Efficiency - Over 95% at full load.
  • Protection Against - Short circuit, under voltage, overload, motor temperature, dead heading, run out, suction loss, sensor fault, bound pump, over voltage, static discharge.
    Note: Suction loss/run out is set for minimum 10 psi at discharge
  • Ambient Temperature - 34_ F to 104_ F
  • Maximum Humidity - 95% at 104_ F, non-condensing
  • Air Pollution - Avoid mounting in areas with excessive dust, acids, corrosives and salts.
  • Approvals - Controller Enclosure - Outdoor, NEMA 3R, IP 43 (Rain-tight)
  • Mounting - Wall mount with mounting hardware.
  • Cooling - Convection with cast aluminum heat sink. - 3 HP, 5 HP with temp. fan.
  • Transducer - 0.5 - 4.5 VDC with 5 VDC power supply, 100 psi range, 80-inch 3-wire shielded cable.
  • Input Wire - 5 feet of 14, 10 or 8 gauge cable. Depending on size, cable is pre-wired to controller and motor conduit box.
  • Output Wire - 10 feet of 14 gauge cable. Cable is pre-wired to controller and pump motor (when provided).
*Low input voltage may affect motor operation.

PRESSURE RANGE

Nominal Range - Field adjustable from 20 - 80 psi, total system pressure.



Locke Well & Pump Company is an independent dealer and is not affiliated with the manufacturers of the products it sells except where expressly noted otherwise.
Any and all trademarks or logo rights associated with the manufacturer's names and products are owned by the respective manufacturers.